Attic Insulation Calculator

Pick your climate zone and measure your current insulation. You'll see the R-value to aim for and how many inches to add.

Most of the northern half of the US is zone 5 or 6.

Recommended attic R-values

These are the ENERGY STAR recommendations for existing homes, based on the 2021 International Energy Conservation Code:

Climate zoneUninsulated atticAttic with 3–4" already
1R30R25
2 and 3R49R38
4 to 8R60R49

This calculator aims for the "uninsulated attic" target, the full recommended level, and subtracts what you already have.

How the calculation works

R you have = existing depth × R per inch of that material

inches to add = (target R − R you have) ÷ R per inch of new material

The R-per-inch figures are typical values: loose fiberglass about 2.2 to 2.7, cellulose about 3.2 to 3.8, and fiberglass batts about 2.9 to 3.8. Check the coverage chart on the bag you buy. It lists the bags per 1,000 sq ft and the settled depth for each R-value.

Worked example

In zone 5 the target is R60. An attic with 4" of old loose fiberglass has about R10, so it needs R50 more. That's 20 inches of blown fiberglass or about 14 inches of cellulose.

Tips

Frequently asked questions

How much attic insulation do I need?

Anywhere from R30 in the warmest zone to R60 in most of the US. In inches, R60 is about 24" of blown fiberglass or 17" of cellulose.

Can I put new insulation on top of old?

Yes, as long as the old insulation is dry and free of mold or pests. Don't put faced batts (with a paper or foil layer) on top of existing insulation, because the facing can trap moisture.